Einkaufswagen  |  Kontakt  | 
Deutschland07056-9398-0
Internationale Rufnummer++49 (0) 7056-9398-0

Eine gute Adresse für Mess- und Regeltechnik aus einer Hand

Flanged Magmeter

FMG-2000

Flanged Magmeter | FMG-2000

Flanged Magmeter

2.700,00 FMG-2004

1 year warranty CE
  • Easy Setup
  • Minimal Straight Pipe
  • Mounted or Remote Rate and Total
  • Tamper-Evident Seal
  • NSF-61 Approved
  • IP68 Rated
  • Touch Screen Programming
  • 200:1 Turndown
Magnetisch-induktive Durchflussmesser - Verwandte Produkte anzeigen

Beschreibung

Find how a Magnetic Flow Meter.works on this link.

The FMG-2000 Series is the most economical flanged electromagnetic flowmeter on the market. It is used in 3 to 12" pipe in municipal or industrial water, wastewater, pump stations and packaged plant applications.

The FMG-2000 has no moving parts and electrodes are designed to discourage fouling. This magmeter requires no maintenance in applications where debris would impede mechanical meters. There are no parts to wear out. Minimal straight pipe requirements allow FMG-2000 Series meters to be used in piping configurations where there is little space between the meter and an elbow. FMG-2000 Series meters are rated IP68 for applications where the meter may be under water up to a depth of 3 m (10') for prolonged periods of time. Rate and total indication are standard. Rate and total units and pulse output are settable via the front panel touch key pad by the user.

The FMG-2000 can be externally powered with 9 to 36 Vdc at 30 mA. The standard 6 m (20') cable also provides outputs for use with a variety of OMEGA® displays and controls for remote reading, data logging and control applications. 4 to 20 mA passive current loop (-I) and high frequency outputs are optional. The FMG-2100 remote display meter can be supplied with an optional internal AC power supply (-120 Vac).

Specifications
Pipe Sizes: 3, 4, 6, 8, 10, and 12"
Flanges: 150 lb. ANSI pattern
Pressure: 150 psi (10.3 bar) working pressure
Temperature
    Operating: -12 to 54°C (10 to 130°F)
    Storage: -40 to 70°C (-40 to 158°F)
    Accuracy: ±1% of reading ±0.04% of full-scale flow from low flow cutoff to maximum flow rate of 10 m/sec
    Low Flow Cutoff: 0.5% of maximum flow rate
Maximum Velocity: 10m/s
Materials
    Body: 3" only ductile cast iron, powder-coated with NSF61 listed epoxy powder 4 to 10" welded steel, epoxy-coated
    Liner: 3" only Noryl® 4 to 12" Santoprene/Polypropylene electronics
    Housing: Ductile cast iron, powder-coated
    Electrodes: 316 stainless steel
    O-ring: 3" only EPDM
Display Type: 128 x 64 dot-matrix LCD
Digits: 5 digit rate, 8 digit total
Power:
    DC power: 9 to 36 Vdc at 250 mA maximum, 30 mA average
    AC Power: Option 85 to 264 Vac, 50/60Hz, 0.12 A
Pulse Frequency Output Signal: Current sinking pulse, isolated, 36 Vdc at 10 mA maximum
Pulse Rates: User-settable volume units/pulse. Pulse width is one-half of pulse period, 200 pulses/sec maximum
Options:
    4 to 20 mA Current Loop (-I): Isolated, passive, 6 to 36 Vdc, ±0.1% of pulse/frequency output HART® compliant
    Digital Output: (-D): Isolated, open collector, 36 Vdc at 10 mA maximum, frequency output up to 10 kHz
    Relay Output (-R): Solid state relay, normally open, non-polarized, 28 Vac/40 Vdc at 0.5A maximum, 33 Hz maximum
Cable:
    Control Cable: Six-conductor water-blocked cable, polyurethane jacket, 6 m (20') standard length for power, pulse frequency or optional outputs; optional lengths up to 30.5 m (100') available
Remote Display Cable (FMG2100): 9 m (30') standard length may be shortened (by user in the field). Additional cable can be ordered and attached with the use of a junction box (purchased from a standard supplier) up to 30.5 m (100') total
Conductivity: >20 microSiemens/cm
Empty Pipe Detection: Hardware/ software, conductivity-based
Regulatory: CE (EN 61326) pending, NSF-61
Environmental: IP68 to 3 m (10') depth
Bestellangaben (Bitte Modellnummer angeben)
Modellnummer/Beschr.
Stk
Beschreibung
FMG-2003 Star
2.425,00
Lieferzeit: 7 Wochen
 
Magmeter with local display, flange Size 7.6 cm (3"), flow Range 3.62 to 723 GPM (0.23 to 46 LPS )
FMG-2004 Star
2.700,00
Lieferzeit: 7 Wochen
 
Magmeter with local display, flange size 10 cm (4"), flow range 6.43 to 1285 GPM (0.41 to 81 LPS)
FMG-2006 Star
2.985,00
Lieferzeit: 1 Woche
 
Magmeter with local display, flange Size 15 cm (6"), flow range 14.5 to 2891 GPM (0.91 to 182 LPS)
FMG-2008 Star
3.245,00
Lieferzeit: 1 Woche
 
Magmeter with local display, flange size 20 cm (8"), flow range 25.7 to 5140 GPM (1.62 to 324 LPS)
FMG-2010 Star
3.670,00
Lieferzeit: 1 Woche
 
Magmeter with local display, flange size 25 cm (10"), flow range 40.15 to 8031 GPM (2.54 to 507 LPS)
FMG-2012 Star
5.255,00
Lieferzeit: 7 Wochen
 
Magmeter with local display, flange Size 30 cm (12"), flow range 57.82 to 11,565 GPM (3.65 to 730 LPS)
FMG-2103 Star
3.595,00
Lieferzeit: 1 Woche
 
Magmeter with remote display, flange size 7.6 cm (3"), flow range flow range 3.62 to 723 GPM (0.23 to 46 LPS)
FMG-2104 Star
3.945,00
Lieferzeit: 1 Woche
 
Magmeter with remote display, flange size 10 cm (4"), flow range 6.43 to 1285 GPM (0.41 to 81 LPS)
FMG-2106 Star
4.040,00
Lieferzeit: 1 Woche
 
Magmeter with remote display, flange size 15 cm (6"), flow range 14.5 to 2891 GPM (0.91 to 182 LPS)
FMG-2108 Star
4.305,00
Lieferzeit: 1 Woche
 
Magmeter with remote display, flange size 20 cm (8"), flow range 25.7 to 5140 GPM (1.62 to 324 LPS)
FMG-2110 Star
4.695,00
Lieferzeit: 1 Woche
 
Magmeter with remote display, flange size 25 cm (10"), flow range 40.15 to 8031 GPM (2.54 to 507 LPS)
FMG-2112 Star
6.375,00
Lieferzeit: 7 Wochen
 
Magmeter with remote display, flange size 30 cm (12"), flow range 57.82 to 11565 GPM (3.65 to 730 LPS)
*Alle Preisangaben in Euro.
Anmerkung: For models with 4 to 20 mA output add “-I” to the model number, for an additional charge.

For models with a digital output add “-D” to the model number, for an additional charge.

For models with a relay output add “-R” to the model number, for an additional charge.

For models powered by 85 to 265 Vac, add “-VAC” to the model number, for an additional charge (Vac option is only available on the FMG-2100 remote display models).

For models with RS485 Modbus RTU protocol communications, add "-M) to the model number, for an additional charge.