Cookies auf den Omega Webseiten
Wir verwenden Cookies auf unserer Webseite. Diese Cookies sind für die ordnungsgemäße Funktion der Webseite unerlässlich. Wenn Sie fortfahren, ohne Ihre Einstellungen zu ändern, gehen wir davon aus, dass Sie alle Cookies auf dieser Webseite akzeptieren.Um weitere Informationen zu diesen Cookies zu erhalten, klicken Sie bitte hier.
SCHLIESSEN
Einkaufswagen  |  Kontakt  | 
Deutschland 07056-9398-0
Internationale Rufnummer++49 (0) 7056-9398-0
Layer N Banner

Hygienic Pt100 Sensors with Integral Cable. For use in CIP Clean-In-Place Applications

PRS-CB Series Hygienic RTD Sensors

Direct Immersion Hygienic Pt100 Sensors with Integral Cable. For Food, Dairy, Brewing and Pharmaceutical Applications | PRS-CB Series Hygienic RTD Sensors

213,01 PRS-3-100-A-S-0300-D1-CB-120

  • 1/4" Diameter Probe Design for Standard Duty, or
    3/8" to 3/16" Stepped Probe Design For Heavy Duty Applications
  • Probe Lengths of 3", 4", 5" and 6" Available From Stock, Other Lengths Also Available
  • Process Connection is a 1½"-16 AMP Tri-Grip™ (Tri-Clamp® Compatible) Standard, Other Sizes and Styles Available. Flanges Conform to ASME BPE-2007 Standard to Assure Trouble Free Interchangeability.
  • Sensor Can be Used in Sanitary, Hygienic and Clean-In-Place Food, Dairy, Beverage and BioPharmaceutical Processes
  • 316L SS Wetted Surfaces with 32 µinch or Better Surface Finish
  • 4-Conductor, 120" Long PFA Cable with Molded Nylon Strain Relief Standard
  • -50 to 200°C (-58 to 392°F) Temperature Range
  • 4-Wire Pt100 Class A Platinum RTD Sensor (100.00±0.06Ω at 0°C) Standard
  • Compatible with 3-Wire and 2-Wire RTD Instruments and Transmitters
Hygienegerecht - Verwandte Produkte anzeigen

Beschreibung

Click on this link if you need more information about Sanitary Sensors.

Sanitary Temperature Sensor Specifications Include:
  • 316L stainless steel process wetted surfaces with surface finishes of 32 microinches or better.

  • Probe lengths of 3, 4, 5 or 6 inches available from stock, other lengths available as special orders.

  • Sensor Output is a 4-wire, 100 ohm, Class A, Platinum RTD meeting the requirements of IEC 60751.

  • These sensors can be used with 2-wire or 3-wire systems see information below.

  • Insulation resistance: 100 megohms minimum at 100 VDC.

  • Thermal response time of less than 2.5 seconds in water flowing at 3 ft/sec (63% response).


  • This Sanitary Temperature Sensor containes a PT100 Platinum RTD element and is designed for use in Food, Dairy, Beverage and BioPharmaceutical Clean-In-Place (CIP) type applications. The sensor includes a 1½" 16AMP process connection that conforms to ASME BPE-2007 for easy installation using industry standard gaskets and clamps. Standard Duty sensors are available with ¼" diameter probes, and Heavy Duty sensors are available with a stepped 38" to 316" diameter probe. This sensor is provided with a 120" long, 4-conductor, #26AWG stranded nickel plated copper, PFA insulated and jacketed cable with a strain relief for convenient connection to control or monitoring equipment.

    Food process hygienic temperature sensors can be used to aid food safety inspection compliance and verification of time temperature control. Combined with a chart recorder model CTXL you can temperature monitor a CCP ( Critical Control Point) or sanitation time and move toward a HACCP (Hazard Analysis Critical Control Point) compliance plan.

    In addition to the standard 1½-16AMP process connection, these can be provided in the following sizes and styles:
    Process ConnectionModel Number Code
    3/4"-16AMP-B1-
    1" and 1½"-16AMP-D1-
    2"-16AMP-E1-
    2½"-16AMP-F1-
    3"-16AMP-G1-
    4"-16AMP-H1-










    If you need a process connection that is not listed above, please contact our sales department for availability.

    These sanitary sensors are supplied standard as 4-wire assemblies with two red wires and two white wires. When used in 3-wire applications, cut off one white wire making sure that it will not contact any terminals or metal surfaces (note: twisting the two white wires together will reduce the lead wire resistance on one side of the sensing element by half adversely affecting the accuracy of the reading). When used in 2-wire applications, cut off one white wire and one red wire (note: in 2-wire applications, twisting the two same-colored wires together at the terminals will not adversely affect your sensor accuracy since both wires will be affected by the reduction in resistance).

    These sensors are also available in Thermistor and Thermocouple styles to accommodate any process input requirement.
    Bestellangaben (Bitte Modellnummer angeben)
    Artikelnummer/Beschr.
    Stk
    Beschreibung
    Standard Duty ¼" Diameter Probe Design
    PRS-3-100-A-S-0300-D1-CB-120
    213,01
    Lieferzeit: 8 Wochen
     
    3" long standard duty probe
    PRS-3-100-A-S-0400-D1-CB-120
    216,65
    Lieferzeit: 8 Wochen
     
    4" long standard duty probe
    PRS-3-100-A-S-0500-D1-CB-120
    216,65
    Lieferzeit: 8 Wochen
     
    5" long standard duty probe
    PRS-3-100-A-S-0600-D1-CB-120
    216,65
    Lieferzeit: 8 Wochen
     
    6" long standard duty probe
    Heavy Duty 3/8" to 3/16" Stepped Probe Design
    PRS-3-100-A-H-0300-D1-CB-120
    268,08
    Lieferzeit: 8 Wochen
     
    3" long heavy duty probe
    PRS-3-100-A-H-0400-D1-CB-120
    268,08
    Lieferzeit: 8 Wochen
     
    4" long heavy duty probe
    PRS-3-100-A-H-0500-D1-CB-120
    268,08
    Lieferzeit: 8 Wochen
     
    5" long heavy duty probe
    PRS-3-100-A-H-0600-D1-CB-120
    268,08
    Lieferzeit: 8 Wochen
     
    6" long heavy duty probe

    Bestellung nach Modellnummer

    Artikelnummer
    Stk
    Artikelnummer
    Stk


    *Alle Preisangaben in Euro.
    Anmerkung: Contact sales for pricing and to order probes with additional sheath and/or cable lengths
    Ordering Example: (1) PRS-3-100-A-S-0400-D1-CB-120 Sanitary RTD sensor with 4-wire Pt100, Class A accuracy element, ¼, €216,65

    Modellkonfigurator

    Stellen Sie Ihre Modellnummer zusammen
    Optionsbeschreibungen:


    (1) Nominal Element Resistance Wählen Sie:
    100 für 100 ohm @ 0 C (standard)
    1000 für 1 kohm @ 0 C

    (2) Probe Diameter Wählen Sie:
    S für Standard Duty 1/4 inch
    H für Heavy Duty 3/8 to 3/16 inch stepped probe

    (3) Probe Length Wählen Sie:
    0300 für 3 inch length
    0400 für 4 inch length
    0500 für 5 inch length
    0600 für 6 inch length

    (4) Sanitary Flange (Cap) Size Wählen Sie:
    D1 für 1-1/2 inch Tri-Grip Flange (standard)
    B1 für 3/4 inch 16AMP Tri-Grip Flange
    E1 für 2 inch 16AMP Tri-Grip Flange
    F1 für 2-1/2 inch 16AMP Tri-Grip Flange
    G1 für 3 inch 16AMP Tri-Grip Flange
    H1 für 4 inch 16AMP Tri-Grip Flange

    (5) Lead Wire Cable Length Wählen Sie:
    120 für 120 inch/10 ft (standard)
    144 für 144 inch/12 ft
    180 für 180 inch/15 ft
    240 für 240 inch/20 ft
    Anmerkung: Nicht alle Optionen können miteinander kombiniert werden, die gültigen Teilenummern entnehmen Sie bitte dem Datenblatt.
    We noticed you are from the US. Visit your local site for regional offers and live support.